 Features
Regulated Converters

2:1 and 4:1 Wide Input Voltage Ranges 1kVDC, 2kVD or 3kVDC Isolation UL94V-0 Package Material Certified for Medical Applications Continuous Short Circuit Protection Low Noise No External Capacitor needed Efficiency to 83 %
ECONOLINE
DC/DC-Converter
Description
High-power-density, an industrial temperature range of -40C to +85C and extra features like Remote-On-Offcontrol are just some of the characteristics of this converter, ideal for highly sophisticated industrial-designs. The RSO series is available with isolation of 2kV or 3kV by chosing option "/H2" or "/H3" in which case it is also ideal for medical applications which additionally require EN-60601-1 certification. The "Z" version features 4:1 input voltage range, while the standard version offers 2:1 input voltage range and includes a low voltage input range down to 4.5V.
Selection Guide
Part Number SIP8 RSO-xx3.3S (H2/H3) RSO-xx05S (H2/H3) RSO-xx09S (H2/H3) RSO-xx12S (H2/H3) RSO-xx15S (H2/H3) RSO-xx3.3D (H2/H3) RSO-xx05D (H2/H3) RSO-xx09D (H2/H3) RSO-xx12D (H2/H3) RSO-XX15D (H2/H3) RSO-xx3.3SZ (H2/H3) RSO-xx05SZ (H2/H3) RSO-xx09SZ (H2/H3) RSO-xx12SZ (H2/H3) RSO-xx15SZ (H2/H3) RSO-xx3.3DZ (H2/H3) RSO-xx05DZ (H2/H3) RSO-xx09DZ (H2/H3) RSO-xx12DZ (H2/H3) RSO-XX15DZ (H2/H3) Input Voltage Range (VDC) 4.5-9, 9-18 18-36, 36-72 4.5-9, 9-18 18-36, 36-72 4.5-9, 9-18 18-36, 36-72 4.5-9, 9-18 18-36, 36-72 4.5-9, 9-18 18-36, 36-72 4.5-9, 9-18 18-36, 36-72 4.5-9, 9-18 18-36, 36-72 4.5-9, 9-18 18-36, 36-72 4.5-9, 9-18 18-36, 36-72 4.5-9, 9-18 18-36, 36-72 9-36 18-72 9-36 18-72 9-36 18-72 9-36 18-72 9-36 18-72 9-36 18-72 9-36 18-72 9-36 18-72 9-36 18-72 9-36 18-72 Rated Output Voltage (VDC) 3.3 5 9 12 15 3.3 5 9 12 15 3.3 5 9 12 15 3.3 5 9 12 15 Output Current (mA) 300 200 111 83 67 150 100 56 42 34 300 200 111 83 67 150 100 56 42 34 Efficiency typ. (%) 68-72 70 73-75 75-78 74-78 78-81 75-80 80-83 75-80 80-83 68-72 70 73-75 75-76 74-78 78 75-79 79-80 75-79 79-80 70 70 78 75 81 78 83 80 83 80 74 70 77 75 78 78 80 80 80 80 Capacitive Load max. 470F 470F 220F 100F 47F 220F 220F 100F 47F 22F 470F 470F 220F 100F 47F 220F 220F 100F 47F 22F
1 Watt SIP8 Isolated Single & Dual Output
2002/95/EC 6/6
RoHS
EN-60950-1 Certified EN-60601-1 Certified (Suffix H2/H3)
RSO
2:1 Input (RS0-S/D) xx = 4.5-9Vin = 05 xx = 9-18Vin = 12 xx = 18-36Vin = 24 xx = 36-72Vin = 48
4:1 Input (RSO-SZ/DZ) xx = 9-36Vin = 24 xx = 18-72Vin = 48
Refer to Application Notes E-81
www.recom-international.com
REV:0/2010
ECONOLINE
DC/DC-Converter
Input Voltage Range Output Voltage Accuracy Line Voltage Regulation Load Voltage Regulation (10% to 100% full load) Output Ripple and Noise (20MHz limited) Operating Frequency Efficiency at Full Load Quiescent Current Nominal input Voltage (Standard, /H2 and /H3) CTRL Pin drive current /see Notes) 2:1 4:1 2:1 4:1 2:1 4:1 RS-05xxS_D RS-12xxS_D RS-24xxS_D, SZ_DZ RS-48xxS_D, SZ_DZ 2:1 and 4:1 2% typ. 0.2% max. 0.5% max. 0.4% max. 0.5% typ. 50mVp-p max. 200kHz min. / 500kHz max. 100kHz min. / 300kHz max. See Selection Guide 40mA typ. 32mA typ. 25mA typ. 15mA typ. 3mA typ, 6mA max.
RSO-S_D(Z) Series
Derating-Graph
(Ambient Temperature)
RSO-S_D
100 80
Specifications (Core Operating Area) measured at TA = 25C, nominal input voltage, full load and after warm-up time unless otherwise specified
Output Power (%)
60 40 30 20 0
Safe Operating Area
Output Power (%)
Quiescent Input Current when Converter is OFF 10mA max. Isolation Voltage (tested for 1 second) 1000VDC min. H2 2000VDC min. H3 3000VDC min. Rated Working Voltage (long term isolation) see Application Notes Isolation Capacitance (1kV version) 2:1 Single 10pF min. / 40pF typ. / 60pF max. Isolation Capacitance (H2 and H3) 2:1 Single 5pF min. / 30pF typ. / 60pF max. Isolation Capacitance (1kV version) 2:1 Dual 120pF min. / 170pF typ. / 250pF max. Isolation Capacitance (H2 and H3) 2:1 Dual 5pF min. / 30pF typ. / 60pF max. Isolation Capacitance (1kV version) 4:1 Single/Dual 200pF max. Isolation Capacitance (H2 and H3) 4:1 Single/Dual 30pF max. Isolation Resistance >1G min. Short Circuit Protection Operating Temperature Range (free air convection) Continuous -40C to +85C (see Graph) -55C to +125C 95% RH 4.7g 22 pcs per Tube
Detailed Information see Application Notes chapter "MTBF"
85 Operating Temperature C
-40
0
50
100
150
RSO-SZ_DZ
100 80 60 40 30 20 0
Safe Operating Area
RS0
Storage Temperature Range Relative Humidity Package Weight Packing Quantity MTBF (+25C) (+85C)
75 Operating Temperature C
-40
0
50
100
150
}
using MIL-HDBK 217F using MIL-HDBK 217F
1685 x 103 hours 254 x 103 hours
Typical Characteristics
RSO-24xxS
Efficiency / Load
100 80 60 40
RSO-all types
2 1.5
2412 2409 Output Power (W) 2405 2415
Efficiency %
20 0
1 0.75 0.5 0
0%
20%
40%
60%
80%
100%
4.5 5
6
7
8
9
Total Output current (%)
Input Voltage (V)
E-82
REV: 0/2010
www.recom-electronic.com
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm)
8 PIN SIP Package
RSO-S_D(Z) Series
3rd angle projection
9.20 11.10 3.80
Single Output
Dual Output
RECOM RSO-xxxx ****
0.500.05
RECOM RSO-xxxx ****
123 5678
RECOM RSO-xxxxD ****
123 5678
0.500.05
XX.X 0.5 mm XX.XX 0.25 mm
Recommended Footprint Details
1.0o+0.15/0
Pin Connections Pin #
1 2 3
Single
-Vin +Vin CTRL NC +Vout -Vout NC*
Dual
-Vin +Vin CTRL NC +Vout Com -Vout
21.80 0.32
Bottom View
2.54
3.20 2.0 2.54
Top View
5 6 7 8
NC = No Connection NC* = NC, but no external Connection allowed.
Notes
Pin 8 (NC*) This pin is used internally and must have no external connection. Pin 5 (NC) Not connected internally. Pin 3 (CTRL) This pin provides an Off function which puts the converter into a low power mode. When the pin is `high' the converter is OFF and when the pin is high `Z' the converter is ON. There is no allowed low state for this pin.
RSO
Application Examples
TTL Remote CTRL Circuit
Control Pin Input Current: 10mA
+Vin 10 KW (see text) Ctrl (TTL) -Vin 4.7 KW 20 KW -Vout RSO/RS/RS3 +Vout
Voltage Set Point Accuracy with external input/output capacitors refer to typ. 1% recommended test circuit: max. 2% Control Pin (CTRL) Input Current, control voltage applied via 1K resistor, output voltage must reduce to 0V:
typ. 3mA max. 6mA
Voltage to be applied via a limiting resistor with a recommended value of 1K for RSO-05xx; 3.3K for RSO-12xx; RSO-24xx and 10K for RSO-48xx.
Isolated Remote CTRL Circuit
+Vin Remote Optocoupler -Vin (see text) -Vout +Vout
RSO/RS/RS3
www.recom-international.com
REV:0/2010
E-83


▲Up To Search▲   

 
Price & Availability of RSO-XX15D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X